Que muestra el video
Este video muestra la relacion entre ComObjects KNX, Group Addresses y mapping hacia Control4.
Puntos del video
- ComObjects KNX.
- Group Addresses KNX.
- Correlacion con el mapping Control4.
Capitulos del video
- 0:00 — Cross-check KNX and Control4
- 0:17 — Inspect actuator correlations
- 1:34 — Review unsupported channels
- 2:34 — Create a mapping manually
- 3:00 — Verify dimmer mappings
Transcripcion completa en ingles
Subtitulos automaticos en ingles del video publicado en YouTube, con normalizacion ligera de nombres de producto.
[0:00] a feature that I really love. now we are in Control4 side. But if we go to the KNX side of the project, we come back to this these menus that we saw previously. suppose that we go to an switching actuator. We can see that this switching actuator has two channels with group addresses. And now that we have the Control4 enabled, we can see that in the group address we have the Control4 simol and this indicates the amount of Control4 devices that are using this group address. And for for every device we have the summary of how many logical devices in Control4 are using this group address. So in actuator that using two definitely two channels we have two devices. This is a crystal clear indication that we
[1:00] have all the devices that we need in this actuator is in Control4 side. The same if for example if you go to the Deli gateway we can see here for example we have the channel 17 we have a device that's called demo house basement gas bedroom ceiling and we can see the group addresses that are being used in that as you can see here we have the regulation DP3 that currently we are not supporting it here basically Basically, we can see that we have two channels, two devices. So, here it's very very easy to spot if all the actuators have the right amount of of Control4 devices. suppose that we have a device that is not there because Control4 couldn't
[2:00] the II couldn't found it. it's not the cases because this project is very accurate and I found everything but we have a very nice feature suppose that this device is not present and you want to add it manually in Control4. You basically select the group address that you want. That is for example the brick brightness value and feedback brightness value. This one you go to right click or plus this is repeated because it's the same group address. You go right click add Control4 device or you click in this plus button and instantly you have a new popup with a device that here for example we call it ceiling ceiling we can select a room kitchen
[3:00] the type is dimmer and the line is automatically picked from the device individual address so it's in is like suggested you can change if you want. And here even though that you can search like always we have added a new feature that you can basically you make a drag and drop. So as you have select these two group addresses you have an ability to make a drag and drop. So this very easily you add a new Control4 device and but of course this is repeated and we can see that we have two ceiling lights in the kitchen. this is something that we don't want but here you can see how this work. I really think that this is very cool feature, something that I miss it a lot because when I was a programmer, I I had to do it device by device and make a a checklist. So this is very easy to cross information between the two platforms.
Resumen tecnico del flujo
Este video de mapping se centra en la relacion entre ComObjects KNX, Group Addresses, DPTs y dispositivos Control4 generados. Muestra por que un dispositivo Control4 normalmente necesita mas de una direccion KNX.
El instalador puede comparar la fuente KNX con la vista Control4 para confirmar direcciones de comando, direcciones de feedback e intencion del datapoint antes del export.
Esto ayuda al diagnosticar problemas de estado. Un comando puede estar bien mientras falta feedback o esta mapeado con la funcion equivocada, por eso el cross-check mantiene ambos lados visibles.