Official product source

KNX to Control4: facts, scope, and limits.

CoduWorks imports an ETS .knxproj file into a cloud workspace, keeps the KNX context available for review, prepares a Control4 structure, and exports a .codu package for its Composer driver. The integrator reviews rooms, devices, group addresses, DPTs, and exceptions before the build. The tool reduces repetitive work; it does not replace professional validation or commissioning.

Reviewed:

How it works

  1. ImportUpload a processable ETS .knxproj.
  2. InterpretThe platform reads topology, locations, devices, ComObjects, GAs, and DPTs.
  3. ReviewConfirm rooms, names, types, mappings, gateways, and warnings.
  4. ExportGenerate the reviewed .codu package.
  5. BuildThe driver shows the plan and creates the supported structure in Composer.
Operating boundary

Generated results, project-specific logic, and feedback paths must be checked before commissioning. Composer and the live KNX installation still require a qualified professional.

Device matrix

TypePublic variantsTreatmentLicense
LightsSwitch, dimmerSupported; review command and feedbackCounted
BlindsPercentage, open/closeSupported; review position, direction, and feedbackCounted
ThermostatsProject templateRequires a template plus setpoint, mode, DPT, and feedback reviewCounted
KNX/IP gatewaysTunnelling, routingSupported; validate network, line, and routeCounted
ContactsBinary/defaultIncluded in the launch offer; review semanticsNo allowance use now
RelaysDefaultIncluded in the launch offer; do not assume every load is a lightNo allowance use now
Motion sensorsDPT 1, 5 %, 5 byte, 18, 20Included in the launch offer; review function and payloadNo allowance use now
Keypad buttonsPress/release, toggle, click on/off, valueIncluded in the launch offer; review eventsNo allowance use now

Buildings, floors, rooms, and areas are project structure and never consume the allowance. Devices or combinations outside this matrix remain context or exceptions until validated; they are not promised as automatic creation.

Known compatibility

ETS
Processable ETS5 and ETS6 .knxproj projects. Encrypted files require their password. CSV, ESF, or OPC can be references but are not equivalent inputs.
Control4
CoduWorks Composer driver. The current Composer/Control4 OS version and dealer environment must be validated before production use.
Output format
Reviewed .codu package for the driver; it is neither a native ETS export nor a third-party driver package.
Maximum upload
200 MB

Security, privacy, and deletion

  • The platform processes account/security data, uploaded project files, mappings, and outputs to provide the service.
  • AI features may send relevant project inputs to AI providers; a professional must review their responses.
  • Access uses accounts, sessions, and project-scoped authorization. The public website does not expose project data.
  • When a project is deleted, heavy KNX relational data is removed. KNX metadata and the Control4 structure are retained in a deleted state for audit/history.
  • Unreferenced temporary extraction directories are pruned after 168 hours. Agent conversation and audit retention is configured to 90 days.
  • For access, correction, erasure, or other privacy requests: info@coduworks.com.

No transmission or storage method eliminates all risk. This description reflects the implementation reviewed on 18 August 2026 and does not replace a contract or DPA.

Public launch pricing

Small Project

150 €300 €Up to 75 counted devices

Big Project

300 €600 €76 to 300 counted devices

Monster Project

Custom301+; priced by project

One-time project license. Only lights, blinds, thermostats, and IP gateways count. Taxes are applied as legally required. Unlimited types are included under the current launch offer and may change in a future offer.

Updates and support

The driver updates through the product, so you do not need to find files or check technical release data. If an update requires action, the product will guide you through it.

Updates
Managed automatically through the product.
Support
info@coduworks.com · Tell us about your project and what you need help reviewing.

Resources for validating the product

These resources show the workflow on a real project, the scope the product can generate, and the checks that remain the installer’s responsibility. Official sources place CoduWorks within the ETS and Control4 ecosystem without presenting third-party products as CoduWorks features.

Frequently asked questions

Direct answers about Control4 KNX integration, ETS6 compatibility, project editing, and supported devices.

How does a Control4 KNX integration work with CoduWorks?
The platform imports the ETS project, keeps topology and group addresses available for review, prepares the Control4 structure, and exports a .codu package. The driver shows the plan and creates only the supported, installer-reviewed structure and devices in Composer.
Does CoduWorks support ETS6 projects?
Yes. It supports processable ETS5 and ETS6 .knxproj files. Encrypted projects need their password, and topology, DPTs, mappings, and feedback must still be validated before commissioning.
Does the product include a Control4 driver editor?
Yes. It combines a cloud editor with KNX and Control4 context, .codu export, and a CoduWorks Composer driver. It is not a native ETS export and does not replace Composer.
Which KNX devices can the Control4 driver create?
The public matrix includes lights, blinds, thermostats, and KNX/IP gateways, plus contacts, relays, motion sensors, and keypad buttons under the visible launch-offer conditions. Each variant requires command, feedback, DPT, and semantic review.

Does it fit your project?

Review the facts first, then validate your environment with us.